Legrand Safety circuit breakers TX3, type A, for alternating and pulsating direct fault currents according to VDE 0664-10, EN 61008-1, undelayed, 2-pin, rated current In 40 A, rated fault current Idn 30 mA, rated voltage Un 230 VAC, rated frequency 50 Hz, shock voltage up to 250 A, rated short circuit breakers 10 kA.
Legrand FI/LS switch DX3, 1-pole with switching neutral conductor, type A, for alternating and pulsating direct fault currents according to EN 61009-1, VDE 0664-20, undelayed, measurement current In 16 A, measurement error current Idn 30 mA.B characteristic, measurement voltage Un 230 VAC, measurement frequency 50 Hz. Fastening to DIN profile rail EN 60715 by latching quick fixes, clear information on the front of each device, unambiguous switching position indicator red/green on switching lever (lockable), with labeling window, with undercut protection for safe insertion of the conductor into elevator terminal, attachment of auxiliary devices possible.
Legrand 665115 NILOE TASTD.RC400 without spreader claws ultrawhite40 -400 W for light and high voltage halogen lamps, 40 - 400 VA for low voltage halogen lampsInserts are supplied including rocker / cover and protective cover. Fastening by means of screws - inserts for screw fastening can be used with spreader claws. 665099 phase cut dimmers 40 - 400 W with soft start / softstop that protects light. Easy and clear operation by 2-button actuation. Own side-position input for conventional lock probes for switching and dimming. 40 -400 W for light and high voltage halogen lamps, 40 - 400 VA for low voltage halogen lamps with conventional (iron core) transformer. Load type: R, L. - 2-wire connection (without neutral conductor), - screw terminals
Legrand Conductor safety switch TX3 according to EN 60898-1, VDE 0641-11, EN 60947-2, 3-pin, C-characteristics, rated current In 20 A, rated switching capacity Icn 10 kA according to EN 60898-1, rated voltage Un 400 VAC, rated frequency 50/60 Hz, energy limiting class 3, fixing on hat profile rail EN 60715. Circuit protection switches with C-characteristics are provided for line protection in devices with high switch-on currents (e.g. motors and transformers).
Legrand FI circuit breaker TX3, type AC, for alternating fault currents. In accordance with EN 61008-1, undelayed, rated voltage 2-pin: 230 V~ / 4-pin: 400 V~, rated frequency 50 Hz , rated short-circuit current Inc 10 kA with suitable pre-locking, shock-proofing up to 250 A, rated switching capacity In=500 A, rated fault switching capacity I Δ, m= 1000 A, fixed on hat profile rail EN 60715.
Legrand Safety switch TX3 according to EN 60898-1, VDE 0641-11, EN 60947-2, 3-pin with switching neutral conductor, C-characteristics, measurement current In 25 A, measurement switching capacity Icn10 kA according to EN 60898-1, measurement voltage Un 400 VAC, measurement frequency 50/60 Hz, energy limiting class 3, attachment to hat profile rail EN 607. Circuit protection switches with C-characteristics are provided for line protection in devices with high switch-on currents (e.g. motors and transformers).
Legrand Fixed circuit breaker TX3, type F-G, mixed frequency sensitive according to EN 62423, VDE 0664-10, EN 61008-1, G according to ÖVE E8601, short-term delayed at least 10 ms, 4-pole, rated current In 40 A, rated fault current Idn 30 mA, rated voltage Un400 VAC, rated frequency 50 Hz.
Legrand Conductor safety switch TX3 according to EN 60898-1, VDE 0641-11, EN 60947-2, 2-pin, B-characteristics, rated current In 10 A, rated switching capacity Icn 6 kA according to EN 60898-1, rated voltage Un 400 VAC, rated frequency 50/60 Hz, energy limiting class 3, fixing on hat profile rail EN 60715. Circuit breakers with B-characteristics are primarily designed for line protection in light and socket circuits.
Legrand Safety circuit breakers TX3, type A, for alternating and pulsating direct fault currents according to VDE 0664-10, EN 61008-1, undelayed, 4-pin, rated current In 40 A, rated fault current Idn 300 mA, rated voltage Un 400 VAC, rated frequency 50 Hz, shock voltage up to 250 A, rated short circuit breakers 10 kA.