Cable carrier Secure detection of lines when the wall is closed. Centering the bore for setting the installation cans. No superfluous insulation material removal. No cover through search bores of hollow wall, C-profiles and insulation materials. Enormous time and cost savings. In combination, only one plunger must be glued, the other cans can be drilled out with the aid of the drill template.
UPC double-walled box 8 hole without screw, bottom-walled box, UP-Dose DUPLEX is suitable for the opposite installation of UP cans in walls from 100 mm, usable can depth is 49 mm, continuous installation in one working step, without complicated installation of two sides, saving time and creating more wiring space, depth: 100 mm, material: PSHI. (24 hours): 35°C, Max. rel. Humidity at 25°C (short term): 90.% Max. relative humidity at 40°C: 50%
With lid, for clamps up to 4 mm2, material thermoplastic, protection: IP20, flame resistance box 650°C according to WDE 0606 Part 1 / DIN IEC 695 Part 2-1 Length: 80 mm Width: 80 mm Depth: 48 mm Halogen-free: Yes
With lid, for clamps up to 4 mm2, material thermoplastic, protection: IP20, flame resistance box 650°C according to WDE 0606 Part 1 / DIN IEC 695 Part 2-1 Length: 100 mm Width: 100 mm Depth: 48 mm Halogen-free: Yes
Flat 4 screw domes for convenient mounting of all built-in devices. Flame resistance 650° C. according to WDE 0606 part 1 / DIN IEC 695 part 2-1. Standard distance of the screw domes 60 mm. Standard distance combination 71 mm. Full-insulated spacer, non-rotational. Introduction for IEC tube up to max. M 25. The pipe automatically engages the inner edge of the tunnel neck and does not project into the interior of the can. Application: Underput. Halogen-free. Ø: 60 mm. Depth: 41 mm, flat. Protection class: IP2X. Number of possible introductions: 6. Measurement voltage: 400W. Material: Polystryrol (PS) Version: without screws
Electronic-Dose Electronic-Dose with 4 screw domes. Material: PS, flame resistance 650°C. According to WDE 0606 part 1 / DIN IEC 695 part 2-1. Introduction: 11 x M20, 6 x M25. The pipe automatically engages the inner edge of the tunnel neck and does not project into the interior of the can. Measurement voltage: 400 W. Halogen-free. Protection class: IP2X. Application: Underput Design: with 2 screws
Diameter 3.2 mm, Self-tapping thread, Corrision resistant, Version: Cross and slot available, Bit size Slot design: Slot depth: 0.8 mm + Tolerance range: 0.2 mm, Slot width: 0.8 mm + Tolerance range: 0.2 mm, Bit size: 1x50 mm or as smallest size 0,6x45 mm, bit size cross design: Philips Size 1 Length: 15 mm Version: slot
Lower-put device blinds, deep 4 screw domes for convenient mounting of all built-in devices. Flame resistance 650° C. according to WDE 0606 part 1 / DIN IEC 695 part 2-1. Standard distance of the screw domes 60 mm. Standard distance combination 71 mm. Full-insulated spacer, non-rotational. Introduction for IEC tube up to max. M 25. The pipe automatically engages the inner edge of the tunnel neck and does not project into the interior of the can. Application: Underput. Halogen-free. Ø: 60 mm. Depth: 62 mm, deep. Protection class: IP2X. Number of possible introductions: 12. Rated voltage: 400W. Material: Polystryrol (PS) Version: without screws
With lid, for clamps up to 4 mm2, material thermoplastic, protection: IP20, flame resistance box 650°C according to WDE 0606 Part 1 / DIN IEC 695 Part 2-1 Length: 150 mm Width: 150 mm Depth: 62 mm Halogen-free: Yes
Diameter 3.2 mm, Self-tapping thread, Corrision resistant, Version: Cross and slot available, Bit size Slot design: Slot depth: 0.8 mm + Tolerance range: 0.2 mm, Slot width: 0.8 mm + Tolerance range: 0.2 mm, Bit size: 1x50 mm or as smallest size 0,6x45 mm, bit size cross design: Philips Size 1 Length: 25 mm
Underput instrumentedosis with 2 screw domes flame resistance 650°C according to WDE 0606 Part 1 / DIN IEC 695 Part 2-1, standard distance of screw domes 60 mm, standard distance combination 71 mm, fully insulated spacer, non-rotational, introduction for IEC tube up to max. M 20. Ø: 60 mm. Depth: 42 mm Version: with 2 screws
Flame resistant 650° C according to WDE 0606 Part 1 / DIN IEC 695 Part 2-1, 8 breakable openings up to Ø 20 mm Diameter: 70 mm Depth: 36 mm Halogen-free: Yes
4 screw domes for comfortable attachment of all built-in devices, flame resistance 650°C according to WDE 0606 Part 1 / DIN IEC 695 Part 2-1, standard distance of screw domes 60 mm, standard distance combination 71 mm, fully insulated spacer, non-rotational, introduction for IEC pipe up to max M 20. Ø: 60 mm. Depth: 42 mm Version: with 2 screws