Hager MCS LS

Hager MCS116 LS switch 16A/1pol/C 6kA, QC circuit breaker 1 polig 6kA C-characteristic 16A Quick Connect 1 module
Hager MCS116 LS switch 16A/1pol/C 6kA, QC circuit breaker 1 polig 6kA C-characteristic 16A Quick Connect 1 module
2-5 days
Circuit breaker 1polig 6kA C-characteristic 16A Quick Connect 1 module Cable protection switch with QuickConnect - terminal DIN EN 60898-1 (VDE 0641 part 11):2003-12; EN 60898-1:2003; EN 60898-1, pr A1:2003, at the exit to 16A and access for the deposit up to 63A. Contact protection according to IP2x DIN VDE 0106 part 100 with VDE Signs. LS with time-delayed thermal trigger for Overload protection and electromagnetic trigger for Short circuit protection. Suitable for retrofit cultivation of Additional equipment; Labeling option directly at Device and individual withdrawal from the phase rail composite by unlatching the quick-fit rail mounting. Rated current: 16 A Trigger characteristic: C Nominal shutdown capacity: 6 kA Number of poles: 1 P Number of modules: 1 Operating voltage AC current: 230/400 V Frequency: 50/60 Hz Connection type: QuickConnect
€6.08
Hager MCS516 LS switch 16A/1pol+N/C 6kA,QC QuickConnect C-16A 2M
Hager MCS516 LS switch 16A/1pol+N/C 6kA,QC QuickConnect C-16A 2M
2-5 days
Rated current: 16 ATrigger characteristic: CNominal shutdown capacity: 6 kANumber of poles: 2 PNumber of modules: 2AC voltage: 230/400 VInsulation voltage: 500 VFrequency: 50/60 HzConnection type: QuickConnectTorque: 2,8NmTotal loss power at rated current: 5.2 WDevice life, electrical switching games: 4000Machine life mechanical switching games: 20000Operating temperature: -25 to 60 °CStorage temperature: -25 to 80 °CHeight installed product: 83.4 mmWide installed product: 35 mmDeep installed product: 70 mm
€11.94
Hager MCS513 LS switch 13A/1pol+N/C 6kA,QC C-13A Quick Connect 2M
Hager MCS513 LS switch 13A/1pol+N/C 6kA,QC C-13A Quick Connect 2M
2-5 days
Circuit breaker 1P+N 6kA C-13A Quick Connect 2MRated current: 13 ATrigger characteristic: CNominal shutdown capacity: 6 kANumber of poles: 2 PNumber of modules: 2AC voltage: 230/400 VInsulation voltage: 500 VFrequency: 50/60 HzConnection type: QuickConnectTorque: 2,8NmTotal loss power under rated current: 4.6 WDevice life, electrical switching games: 4000Machine life mechanical switching games: 20000Operating temperature: -25 to 60 °CStorage temperature: -25 to 80 °CHeight installed product: 83.4 mmWide installed product: 35 mmDeep installed product: 70 mm
€11.94
Hager MCS616 LS switch 16A/3pol+N/C 6kA,QC C-16A Quick Connect 4M
Hager MCS616 LS switch 16A/3pol+N/C 6kA,QC C-16A Quick Connect 4M
2-5 days
Rated current: 16 ATrigger characteristic: CNominal shutdown capacity: 6 kANumber of poles: 4 PNumber of modules: 4AC voltage: 230/400 VInsulation voltage: 500 VFrequency: 50/60 HzConnection type: QuickConnectTorque: 2,8NmTotal loss power at rated current: 8.2 WDevice life, electrical switching games: 4000Machine life mechanical switching games: 20000Operating temperature: -25 to 60 °CStorage temperature: -25 to 80 °CHeight installed product: 83.4 mmWide installed product: 70 mmDeep installed product: 70 mm
€58.33
Hager MCS113 LS switch 13A/1pol/C 6kA, QC QuickConnect
Hager MCS113 LS switch 13A/1pol/C 6kA, QC QuickConnect
2-5 days
Circuit breaker 1polig 6kA C-Characteristic 13A Quick Connect 1 module Circuit breaker with QuickConnect terminal according to DIN EN 60898-1 (VDE 0641 part 11):2003-12; EN 60898-1:2003; EN 60898-1, pr A1:2003, at the exit up to 16A and at the access for the concealment up to 63A. LS with time-delayed thermal trigger for overload protection and electromagnetic trigger for short-circuit protection. Suitable for retrofit installation of additional equipment; Possibility of marking directly on the device and individual removal from the phase rail composite by unlocking the quick attachment of the hat rails. Rated current: 13 ATrigger characteristic: CNominal shutdown capacity: 6 kANumber of poles: 1 PNumber of modules: 1AC voltage: 230/400 VInsulation voltage: 500 VFrequency: 50/60 HzConnection type: QuickConnectTorque: 2,8NmTotal loss power at rated current: 2,3 WDevice life, electrical switching games: 4000Machine life mechanical switching games: 20000Operating temperature: -25 to 60 °CStorage temperature: -25 to 80 °CHeight installed product: 83.4 mmWide installed product: 17.5 mmDeep installed product: 70 mm
€6.08
Hager MCS316 LS switch 16A/3pol/C 6kA, QC QuickConnect cable protection switch 3 polig 6kA C-characteristics 16A 3 modules
Hager MCS316 LS switch 16A/3pol/C 6kA, QC QuickConnect cable protection switch 3 polig 6kA C-characteristics 16A 3 modules
2-5 days
3polig 6kA C-characteristic 16A Quick Connect 3 Modules Cable protection switch with QuickConnect - terminal DIN EN 60898-1 (VDE 0641 part 11):2003-12; EN 60898-1:2003; EN 60898-1, pr A1:2003, at the exit to 16A and access for the deposit up to 63A. Contact protection according to IP2x DIN VDE 0106 part 100 with VDE Signs. LS with time-delayed thermal trigger for Overload protection and electromagnetic trigger for Short circuit protection. Suitable for retrofit cultivation of Additional equipment; Labeling option directly at Device and individual withdrawal from the phase rail composite by unlatching the quick-fit rail mounting. Rated current: 16 A Trigger characteristic: C Nominal shutdown capacity: 6 kA Number of poles: 3 P Number of modules: 3 Operating voltage AC current: 230/400 V Frequency: 50/60 Hz Connection type: QuickConnect
€33.36
Hager MCS332 LS switch 3P 6kA C-32A QC QuickConnect 3M circuit breaker 3 polig 6kA C-characteristic 32A 3 modules
Hager MCS332 LS switch 3P 6kA C-32A QC QuickConnect 3M circuit breaker 3 polig 6kA C-characteristic 32A 3 modules
2-8 days
3polig 6kA C-Characteristic 32A QuickConnect 3 Module cable protection switch with QuickConnect terminal according to DIN EN 60898-1 (VDE 0641 part 11):2003-12; EN 60898-1:2003; EN 60898-1, pr A1:2003, at the exit up to 16A and at the access for the concealment up to 63A. LS with time-delayed thermal trigger for overload protection and electromagnetic trigger for short-circuit protection. Suitable for retrofit installation of additional equipment; Possibility of marking directly on the device and individual removal from the phase rail composite by unlocking the quick attachment of the hat rails.Trigger characteristic:CNominal deactivation capacity:6Number of poles:3 PNumber of modules:3AC voltage:OF 230/400 VInsulation voltage:500 VFrequency:50/60 HzConnection type:QuickConnectTorque:2.8 NmTotal power loss under rated current:13 WDevice life, electrical switching games:4000Machine life mechanical switching games:20000Operating temperature:-25 to 60 °CStorage temperature:-25 to 80 °CHeight installed product:83.4 mmWide installed product:52.5 mmDeep Installed Product:70 mm
€57.09
Hager MCS320 LS switch 3P 6kA C-20A QC circuit breaker 3 polig 6kA C-characteristics 20A QuickConnect 3 modules
Hager MCS320 LS switch 3P 6kA C-20A QC circuit breaker 3 polig 6kA C-characteristics 20A QuickConnect 3 modules
2-8 days
3polig 6kA C-Characteristic 20A QuickConnect 3 Module cable protection switch with QuickConnect terminal according to DIN EN 60898-1 (VDE 0641 part 11):2003-12; EN 60898-1:2003; EN 60898-1, pr A1:2003, at the exit up to 16A and at the access for the concealment up to 63A. LS with time-delayed thermal trigger for overload protection and electromagnetic trigger for short-circuit protection. Suitable for retrofit installation of additional equipment; Possibility of marking directly on the device and individual removal from the phase rail composite by unlocking the quick attachment of the hat rails.Rated current:20 ATrigger characteristic:CNominal deactivation capacity:6Number of poles:3 PNumber of modules:3AC voltage:OF 230/400 VInsulation voltage:500 VFrequency:50/60 HzConnection type:QuickConnectTorque:2.8 NmTotal power loss under rated current:8.9 WDevice life, electrical switching games:4000Machine life mechanical switching games:20000Operating temperature:-25 to 60 °CStorage temperature:-25 to 80 °CHeight installed product:83.4 mmWide installed product:52.5 mmDeep Installed Product:70 mm
€50.03
Hager MCS625 cable protection switch 3P+N 6kA C-25A Quick Connect 4M
Hager MCS625 cable protection switch 3P+N 6kA C-25A Quick Connect 4M
2-5 Tage
Rated current:25 ATrigger characteristic:CNominal deactivation capacity:6Number of poles:4 PNumber of modules:4AC voltage:OF 230/400 VInsulation voltage:500 VFrequency:50/60 HzConnection type:QuickConnectTorque:2.8 NmTotal power loss under rated current:10.1 WDevice life, electrical switching games:4000Machine life mechanical switching games:20000Operating temperature:-25 to 60 °CStorage temperature:-25 to 80 °CHeight installed product:83.4 mmWide installed product:70 mmDeep Installed Product:70 mm
€86.44
Hager MCS313 LS switch 13A/3pol/C 6kA, QC circuit breaker 3 polig 6kA C-characteristic 13A QuickConnect 3 modules
Hager MCS313 LS switch 13A/3pol/C 6kA, QC circuit breaker 3 polig 6kA C-characteristic 13A QuickConnect 3 modules
2-8 days
3polig 6kA C-Characteristic 13A QuickConnect 3 Module cable protection switch with QuickConnect terminal according to DIN EN 60898-1 (VDE 0641 part 11):2003-12; EN 60898-1:2003; EN 60898-1, pr A1:2003, at the exit up to 16A and at the access for the concealment up to 63A. LS with time-delayed thermal trigger for overload protection and electromagnetic trigger for short-circuit protection. Suitable for retrofit installation of additional equipment; Labeling option directly on the device and individual removal from the phase rail connection by unlocking the quick-fitting hat railRated current:13 ATrigger characteristic:CNominal deactivation capacity:6Number of poles:3 PNumber of modules:3AC voltage:OF 230/400 VInsulation voltage:500 VFrequency:50/60 HzConnection type:QuickConnectTorque:2.8 NmTotal power loss under rated current:6.7 WDevice life, electrical switching games:4000Machine life mechanical switching games:20000Operating temperature:-25 to 60 °CStorage temperature:-25 to 80 °CHeight installed product:83.4 mmWide installed product:52.5 mmDeep Installed Product:70 mm
€33.36