Hager CDA225D fault current switch 2 polig 6kA 25A 30mA Type A
3-8 working days
Residual current circuit breaker 2-pole 6kA 25A 30mA type A. Residual current circuit breaker (FI) according to EN 61008-1, DIN EN 61008-2-1, VDE 0664 part 10 + 11, protection against accidental contact IP2x according to DIN VDE 0106 part 100 .Suitable for retrofitting additional equipment (mounting without tools). Wire push-in protection terminals, bottom bi-connect terminals, external blue test button. All products with VDE mark. Labeling option directly on the device.
Rated current
25A
Type of differential protection
A
Sensitivity
30mA
Number of Poles
2P
Surge current resistance (pulse fault currents 8/20µs)
0.25kA
Number of modules
2
Frequency
50Hz
Mounting type
DIN rail
Type of connection
screw technology
Connection cross section with flexible conductor
16mm²
Connection cross section with rigid conductor
25mm²
torque
2.8Nm
degree of protection
IP20
Insulation voltage
500V
Surge withstand voltage
4kV
Additional equipment possible
1
Operating temperature
-25 to 40 °C
Device lifetime mechanical switching cycles
4000
Device service life, electrical switching cycles
2000
Total power loss under rated current
3.4W
Degree of contamination according to IEC 60664 / IEC 60947-2
2
Height above sea level
2000m
Rated current at 20° C
25A
Rated current at 30° C
25A
Rated current at 35° C
25A
Rated current at 40° C
25A
Rated current at 45° C
25A
Rated current at 50°C
25A
Rated current at 55° C
25A
Rated current at 60°C
25A
Rated current at 65°C
25A
Rated current at 70°C
21A
Storage temperature
-55 to 70 °C
Height installed product
83mm
Wide installed product
35mm
Deep Installed Product
70mm
Rated current
25A
Type of differential protection
A
Sensitivity
30mA
Number of Poles
2P
Surge current resistance (pulse fault currents 8/20µs)
0.25kA
Number of modules
2
Frequency
50Hz
Mounting type
DIN rail
Type of connection
screw technology
Connection cross section with flexible conductor
16mm²
Connection cross section with rigid conductor
25mm²
torque
2.8Nm
degree of protection
IP20
Insulation voltage
500V
Surge withstand voltage
4kV
Additional equipment possible
1
Operating temperature
-25 to 40 °C
Device lifetime mechanical switching cycles
4000
Device service life, electrical switching cycles
2000
Total power loss under rated current
3.4W
Degree of contamination according to IEC 60664 / IEC 60947-2
2
Height above sea level
2000m
Rated current at 20° C
25A
Rated current at 30° C
25A
Rated current at 35° C
25A
Rated current at 40° C
25A
Rated current at 45° C
25A
Rated current at 50°C
25A
Rated current at 55° C
25A
Rated current at 60°C
25A
Rated current at 65°C
25A
Rated current at 70°C
21A
Storage temperature
-55 to 70 °C
Height installed product
83mm
Wide installed product
35mm
Deep Installed Product
70mm
€68.04