List of products by brand Eltako

Eltako TLZ12-8 Staircase Time Clock
Eltako TLZ12-8 Staircase Time Clock
3-10 days
Rated voltage: 50 %. Bulb load: 2000 W Max. Lamp load: 1000 VA Max. Fluorescent lamp load (Duo circuit): 1000 VA Max. Fluorescent lamp load (parallel compensated): 500 VA stairlight time switch, without switch-off warning. Stand-by-loss only 0.7 Watt. Time setting about 0.2 to 12 minutes. Own continuous light switch with the large rotary switch. For 3- and 4-wire circuits, switchable, with attic lighting at 4-wire circuit. Automatic detection of the circuit type. Without disconnection and contact circuit in the zero passage. With double connections for probe and lamp, so that it can be connected either at the top and bottom or only at the bottom.
€35.63
Eltako ES12DX-UC power surge switch
Eltako ES12DX-UC power surge switch
3-10 days
Current surge switches, electronic for mounting on support rail DIN-EN 60715 TH35 potential-free 16A/250V AC, incandescent lamps 200W No stand-by loss, maximum current as a sum over both contacts 20A at 230V, connection terminal occupancy is identical with current surge switches S12 current surge switches, stand-by consumption of only 0.1 Watt. If the contact is used for controlling switching devices which themselves do not switch in the zero passage, (N) should not be connected, since the additional closing delay otherwise causes the opposite. The simultaneous use of two potentials at the tax inputs is not permissible. Very low switching noise. No constant power supply required, therefore no stand-by loss. The most modern hybrid technology combines the advantages of wear-free electronic control with the high power of special relays. By using a bistable relay, there is no coil loss power and no heating as a result even in the switched-on state. The relay contact can be open or closed during commissioning and synchronizes during the first actuation. The connection terminal occupancy is identical to the electromechanical current surge switch. Width in division units: 1 Number of locks: 1 Rated switching current: 16 A Control voltage type 1: AC/DC Installation depth: 58 mm Function: electronic switch Mounting type: DIN rail Frequency of control voltage 1: 50 - 50 Hz Voltage type of supply voltage: AC Supply voltage range: 250 - 250 W Max. Bulb load: 2000 W Max. Lamp load: 1000 VA Max. Fluorescent lamp load (Duo circuit): 1000 VA Max. Fluorescent lamp load (parallel compensated): 500 VA Max. Switching current (cos phi = 0.6): 4 A manual operation possible: No
€41.63
Eltako ER12 DX-UC Universalsp. Relay
Eltako ER12 DX-UC Universalsp. Relay
3-10 days
Switching relay for mounting on support rails DIN-EN60715 TH35 No heat losses due to internal bistable relay,DX=Eltako-Duplex technology, switch in the zero crossing of the sine wave of a 230V switching voltage, low switching noise, control indicator with light-emitting diode, integrated freewheel/lowering diode (A1 =+, A2 =−) switching relays. No standby loss. The most modern hybrid technology combines the advantages of wear-free electronic control with the high power of special relays. To this end, simply connect the N conductor to the terminal (N) and L to 1 (L). This results in a stand-by consumption of only 0.1 Watt. If the contact is used for controlling switching devices which themselves do not switch in the zero passage, (N) should not be connected, since the additional closing delay otherwise causes the opposite. Very low switching noise. Control indicator with light-emitting diode. The connection terminal occupancy is identical to the electromechanical switching relay R12-100-. By using a bistable relay, there is no coil loss power and no heating as a result even in the switched-on state. The relay contact can be open or closed during commissioning and synchronizes during the first actuation. This relay is not suitable for feedback with the switching voltage of a dimming switch. The electronics have no own power supply and therefore no stand-by loss. Only when the control contact is closed is the microcontroller which switches the bistable relay in the correct direction. When the control contact is opened or a falling control voltage is switched back. TLE: 1 Number of contacts as closer: 1 Rated control voltage Us at AC 50 Hz: 8 - 230 V
€41.63
Eltako TLZ61NP-8..230VUC Stair switch. UP
Eltako TLZ61NP-8..230VUC Stair switch. UP
3-10 days
Steplight time switch, electronic for UP mounting, built-in device quietly and timely, max. 50ma Glow lamp current, time range stepless to 10 minutes adjustable, 4-wire switchable, rated switching power 10 A/250 W AC, control voltage 8...230 W UC Stair switch 230V+UC. 1 lock not potential-free 10A/250V AC, incandescent lamps up to 2000W, ESL and LED lamps up to 200W, switch-off warning and push-button continuous light. Stand-by-loss only 0.7 Watt. With ESL optimization. For installation. 45mm long, 45mm wide, 18mm deep. Contact circuit in the zero passage for protecting the contacts and lamps. In particular, this extends the service life of energy-saving lamps. By using a bistable relay, there is no coil loss power and no heating as a result even in the switched-on state. After installation, wait for the automatic short synchronization before the switched consumer is placed on the network. Control, supply and switching voltage 230W. In addition with galvanically separated universal control voltage 8..230V UC. Time setting 1 to 12 minutes. Glow lamp current up to 50ma, depending on the ignition voltage of the glow lamps. For 3- and 4-wire circuits, switchable, with attic lighting at 4-wire circuit. Automatic detection of the circuit type. After a power failure, the illumination is switched on again when the time sequence has not yet been completed. When switched off, the lighting flickers approx. 30 seconds before the time sequence beginning and a total of 3 times in shorter time intervals. When the pushbutton permanent light is switched on, it is possible to set for longer than 1 second by means of buttons, which is switched off automatically after 60 minutes or can be switched off with buttons for longer than 2 seconds. If the pushbutton continuous light and the switch-off pre-warning are switched on, the switch-off pre-warning takes place after the switch-off of the continuous light. All or part of
€44.37
Eltako ES12-200-UC 8..230V UC power surge switch
Eltako ES12-200-UC 8..230V UC power surge switch
3-10 days
Power surge switch, electronic for mounting on support rail DIN-EN 60715 TH35 potential-free 16A/250V AC, incandescent lamps 200W No stand-by loss, maximum current as the sum of both contacts 20A at 230V, connection terminal occupancy is identical with current surge switch S12 width in division units: 1 Number of switches: 2 Rated switch current: 16 A. Bulb load: 2000 W Max. Lamp load: 1000 VA Max. Fluorescent lamp load (Duo circuit): 1000 VA Max. Fluorescent lamp load (parallel compensated): 500 VA Max. Switching current (cos phi = 0.6): 4 A manual operation possible: No power surge switch UC. No standby loss. Either universal control voltage 8..230V UC at the control input +A1/-A2 or 230W with up to 5ma glow lamp current at the control input with glow lamp symbol (L)/-A2(N). The simultaneous use of two potentials at the tax inputs is not permissible. Very low switching noise. No constant power supply required, therefore no stand-by loss. The most modern hybrid technology combines the advantages of wear-free electronic control with the high power of special relays. By using a bistable relay, there is no coil loss power and no heating as a result even in the switched-on state. The relay contact can be open or closed during commissioning and synchronizes during the first actuation. Maximum current as a sum of both contacts 16A at 230W.
€44.92
Eltako MFZ12-230V Multifunction time relay
Eltako MFZ12-230V Multifunction time relay
3-10 days
Multifunction time relay 230W with 10 functions, 1 lock potential-free 10A/250V AC, incandescent lamps 1000W, stand-by-loss 0.4 Watt, series installation device for mounting on support rail DIN-EN 60715 TH35 Analog adjustable multifunction time relay with 10 functions. Stand-by loss only 0.4 Watt. Times between 0.1 seconds and 40 hours are adjustable. Functions F: RV = relapse delay. AV = response delay. TI = clock generator starting with pulse. TP = clock generator starting with pause. IA = impulse-controlled response delay (e.g. automatic door opener). EW = turn-on wiper. AW = switch-off wiper. ARV = response and relapse delay. ON = duration ON. OFF = duration AUS. The light-emitting diode under the large rotary switch informs about the contact position during the time sequence. It flashes as long as the working contact is open and illuminates continuously as long as the working contact is closed. The time base T is set with the central latching rotary switch T. Width in division units: 1 control voltage 1: 230 - 230 W control voltage type 1: AC frequency of control voltage 1: 50 - 50 Hz switching power fluorescent lamps parallel: 250 VA 1. Time range from/to: 40 - 0.1 Function: Multifunction Number of locks: 1 Number of openers: 0 Number of switchovers: 0 Voltage type of supply voltage: AC Switching power bulbs: 1000 W Supply voltage range: 230 - 230 W Switching power Luminous lamps inductor: 500 VA Mounting height: 58 mm Rated current at 250 W AC: 10 A Switching power Luminous lamps DUO: 500 VA. Time unit: minutes/hour assembly type: DIN rail
€47.10
Eltako SNT12-230V/24VDC-0.5A switching power supply
Eltako SNT12-230V/24VDC-0.5A switching power supply
3-10 days
Switching power supplies for mounting on support rail DIN-EN 60715 TH3Stand-by-loss 0.2 Watt, short-circuit-proof, with a load greater than 50% of the rated power and always with adjacent switching power supplies above 12 Watt rated power and with dimmers a 1/2 division of ventilation unit with spacers DS12 is required, input voltage 230W AC, -(20% to +10)%, efficiency 12W DC 83%, 24W DC. With a load greater than 50% of the rated power and always with adjacent switching power supply components greater than 12 watts of rated power, and with dimmers, a 1/2 division unit is required on both sides with the distance pieces DS12. Efficiency 24W DC 86%. Stabilized output voltage ±1%, low residual ripple. Short circuit. Overload and overtemperature protection by switching off with automatic switching on after eliminating errors (autorecovery function).
€50.38
Eltako RVZ12DX-UC time relay
Eltako RVZ12DX-UC time relay
3-10 days
Multifunction time relays for mounting on support rail DIN-EN 60715 TH35, for all control voltages from 8 to 230W DC and AC (50/60 Hz), times between 0.1 seconds and 40 hours with the time bases 0.1, 0.5, 2 and 5 seconds, 1, 2 and 5 minutes, 1, 2 and 4 hours as well as the multiplier of 1-10 are adjustable, contact circuit in the zero crossing of the sinus wave, 0.1 Watt-by-adjustable time. Stand-by-loss only 0.02 - 0.4 Watt. This analog adjustable time relay is identical to the multifunction time relay, but has only one function. To this end, simply connect the N conductor to the terminal (N) and L to 15 (L). This results in an additional stand-by consumption of only 0.1 Watt. Universal control voltage 8..230V UC. Supply voltage like the control voltage. Time range from 0.1 seconds to 40 hours. By using a bistable relay, there is no coil loss power and no heating as a result even in the switched-on state. After installation, wait for the automatic short synchronization before the switched consumer is placed on the network. The light-emitting diode under the large rotary switch informs about the contact position during the time sequence. control voltage 1: 8 - 230 W control voltage type 1: AC/DC switching power fluorescent lamps parallel: 500 VA 1. Time range from/to: 40 - 0.1 Function: Relapse delay Number of switches: 1 Switching power Incandescent lamps: 2000 W Width in division units: 1 Supply voltage range: 8 - 230 W Switching power Fluorescent lamps inductor: 1000 VA Mounting height: 58 mm Switching power Fluorescent lamps DUO: 1000 VA. Time unit: minutes/hour assembly type: DIN rail
€52.56
Eltako AR12DX-230V power relay
Eltako AR12DX-230V power relay
3-10 days
Current relays for mounting on support rail DIN-EN 60715 TH35, potential-free 16 A /250 W AC, stand-by loss only 0.8 Watt current relay, stand-by loss only 0.8 Watt. Mounting unit for mounting on support rail (1 TE). To this end, simply connect the N conductor to the terminal (N) and L to 1 (L). This results in an additional stand-by consumption of only 0.1 Watt. If the contact is used for controlling switching devices which themselves do not switch in the zero passage, (N) should not be connected, since the additional closing delay otherwise causes the opposite. With an internal ring core current converter, the alternating current flowing via a consumer W1 is compared with the set value from 0.1A to a maximum of 32A and, when exceeded, a relay switches off a consumer W2 connected to 2 within 0.5 seconds or a consumer W3 connected to 3. Adjustment accuracy ±5%. From 25A, the relay always switches on. The most modern hybrid technology combines the advantages of wear-free electronic control with the high power of special relays. The current base A is set with the lower latching rotary switch A. TLE: 1 Number of contacts as changer: 1 Rated control voltage Us at AC 50 Hz: 230 - W
€58.03
Eltako WSZ15DE-32A AC counter
Eltako WSZ15DE-32A AC counter
3-10 days
Electronic AC meter AC counters without approval for support rail. Stand-by loss only 0.5 Watt. Accuracy class B (1) % With S0 interface. This alternating current meter measures the active energy on the basis of the current flowing between the input and the output. The own consumption of only a maximum of 0.5 watt active power is not measured and not displayed. Like all counters without PTB or MID approval in Germany not approved for monetary current billing. Every 30 seconds, the display switches from the accumulated active energy to the instantaneous consumption in Watt for 5 seconds. 1 external conductor can be connected with a current up to 32A. In the event of a load to be expected of more than 50%, a ventilation distance of 1/2 division unit is to be maintained for devices mounted next to it. If the spacer DS12 is used. The starting current is 20ma. The display can only be read with power supply. However, the consumption is non-volatile and will be displayed immediately after a power failure. Two N-terminals for secure cross wiring of several counters. The decimal point which flashes depending on the power consumption indicates a power reference. In case of false connection, false appears in the display. The digital display has 7 digits. Up to 99999,99kWh, two descendants are displayed. From 100000.0kWh only one. Even with only theoretically conceivable maximum current reference, the display would be suitable for more than 15 years. The power reference is displayed with the decimal point. TLE: 1 Certified: No Measurement voltage: 230 W
€59.02
Eltako ETR61NP-230V+FK separation relay
Eltako ETR61NP-230V+FK separation relay
3-10 days
Disconnection relays with window contact 1 closer not potential-free 10A/250V AC, stand-by loss only 0.5 Watt, for installation and AP installation, hybrid technology combines the advantages of wear-free electronic control with the high power of special relays, control input with internally generated low voltage 24W DC, with a disconnection transformer galvanically separated from the power supply and the working contact (PELaisV), therefore no external low voltage. 1 lock not potential-free 10A/250V AC. With window contact. Stand-by loss only 0.5 Watt. For installation. 45mm long, 45mm wide, 18mm deep. The most modern hybrid technology combines the advantages of wear-free electronic control with the high power of special relays. Control input with internally generated low voltage 24W DC. galvanically separated from the power supply and the working contact (PELV). Therefore, no external low-voltage power supply is required. With two L-terminals and 2 N-terminals for easy and fast installation. Power supply 230W. The enclosed window contact consists of a reed relay with connection terminals and a magnet. The normally closed contact opens as soon as the magnet has come closer than 25mm. Connected to the terminals T1 and T2 of the separating relay ETR61NP, the power supply of a rod train is switched on as long as the window is open. The ETR61NP can be placed in the UP-Dose behind the outlet for the Dunstabzug. Installation of the window contact FK: On the housing-painted side, lever the inserts out. Connect Reedrelais and cut out housing section for the line. Both housings maximum 15mm
€60.76
Eltako SNT12-230V/12VDC-2A power supply
Eltako SNT12-230V/12VDC-2A power supply
3-10 days
Switching power supplies for mounting on support rail DIN-EN 60715 TH3Stand-by-loss 0.2 Watt, short-circuit-proof, with a load greater than 50% of the rated power and always with adjacent switching power supplies above 12 Watt rated power and with dimmers a 1/2 division of ventilation unit with spacers DS12 is required, input voltage 230W AC, -(20% to +10)%, efficiency 12W DC 83%, 24W DC. With a load greater than 50% of the rated power and always with adjacent switching power supply components greater than 12 watts of rated power, and with dimmers, a 1/2 division unit is required on both sides with the distance pieces DS12. Efficiency 12W DC 83%. Stabilized output voltage ±1%, low residual ripple. Short circuit. Overload and overtemperature protection by switching off with automatic switching on after eliminating errors (autorecovery function).
€62.41
Eltako FRP61-230V Radio Repeater
Eltako FRP61-230V Radio Repeater
3-10 days
Radio repeater for installation and AP installation, this repeater is only required if the structural conditions prevent an undisturbed reception or the distance between radio probe and receiver is too large, from work the 1-level mode is activated but also can be adjusted to level 2, radio repeater need not be learned, they receive and amplify the signals from all radio sensors in their reception area, only supply voltage required, standby level 1. Stand-by loss only 0.9 Watt. For installation. 45mm long, 45mm wide, 33mm deep. This repeater is only required if the structural conditions prevent an undisturbed reception, or the distance between radio button and receiver is too large. The 1-level mode is set from work. Only the radio signals are received, tested and transmitted with full transmission power. Radio signals from other repeaters are ignored to reduce the amount of data. The rotary switch can be switched to the 2-level mode. In addition to the radio signals from sensors, the radio signals from another 1-level repeater are also processed. A radio signal can thus be received and amplified at most twice. The LED displays incoming radio signals by short flashing. Radio-repeaters do not have to be learned. They receive and amplify the radio signals from all radio sensors in their reception area.
€72.14
Eltako S2U12DDX-UC 2-channel clock
Eltako S2U12DDX-UC 2-channel clock
3-10 days
2-channel weekly switch clock 1+1 closer potential-free 16A/250V AC, 60 switch clock memory locations, power reserve 2 weeks, stand-by loss max. 0.4 Watt, automatic summer winter time switch and pulsed, with astro function, additional control input for the central on or off 2-channel clock with astro function. Stand-by loss only 0.03-0.4 watts. To this end, simply connect the N conductor to the terminal (N) and L to 1(L) and/or 3(L). This results in an additional stand-by loss of only 0.1 Watt. Due to the use of bistable relays, there is no coil loss power and no heating thereby even in the switched-on state. Up to 60 switching clock memory locations are distributed freely on the channels. With date and automatic summer/winter time conversion. Power reserve without battery about 7 days. Each storage space can be occupied either with the astro function (automatic switching after sunrise or sunset), the switch-on and switch-off time or a pulse switching time (in which a pulse of 2 seconds is triggered). The switch-on or switch-off time Astro can be shifted ± 2 hours and, in addition, from the manufacturing week 19/2012, a time shift of up to ± 2 hours influenced by the sun. With control input +(A1) for central control ON or OFF with priority. Supply voltage and control voltage for central control 8..230V UC. The switching clock is set with the MODE and SET keys and a key lock is possible. Set language: After each application of the supply voltage, the language can be selected with SET within 10 seconds and confirmed with MODE. D = German, GB = English, F = French, IT = Italian and ES = Spanish. Then the normal display appears: weekday, time, day and month. Quick run: In the following settings, the numbers run quickly when the input key is pressed longer
€76.07
Eltako FSM61-UC Radio transmitter module
Eltako FSM61-UC Radio transmitter module
3-10 days
Radio transmitter module for installation, radio 2x transmitter module with internal antenna, no stand-by loss radio 2x transmitter module. With internal antenna. No standby loss. For installation. 45mm long, 45mm wide, 18mm deep. The radio transmitter module FSM61-UC has two channels and can thus be radio telegrams in the Eltako- Send building radio. A1 causes a radio telegram, such as rocker, to press a radio button with a rocker and A3 like rocker at the bottom. The telegram when opening the two control contacts is identical to that of the radio button. Several radio transmission modules must not be simultaneously controlled. The universal control voltage at +An/-A2 processes control commands from 8 to 253V AC or 10 to 230V DC with a length of at least 0.2 seconds. Maximum parallel capacity of the control lines at 230V 5nF. This corresponds to a length of about 20 meters. If the terminals A1 and A3 are connected to a bridge, a spark telegram of A3 is transmitted 1× per minute as long as the control voltage is applied. For example, for central commands with priority. No constant power supply required, therefore no stand-by loss. The rotary switch is used for activation or. Deactivation of the encryption is required and is in operation on AUTO. Enable encryption: Turn the rotary switch to right stop (position key) and once buttons. Disable encryption: Turn the rotary switch to left stop (position of broken key) and once buttons. Number of commands: 2 Rolling code system: No Radio hand transmitter: No Radio button under plaster: No Radio button on plaster: No Radio coder: Yes Keyboard protection cover: No
€77.71