List of products by brand Eaton

Eaton PFIM-40/4/003-XG/A FI-Schutzschalter A 40A/4 30mA 'XG/A' 3kA
On sale!-12%
Eaton PFIM-40/4/003-XG/A FI circuit breaker A 40A/4 30mA 'XG/A' 3kA 235743
1-5 Tage




Polzahl



4



Bemessungsspannung


V
400



Bemessungsstrom


A
40



Bemessungsfehlerstrom


A
0.03



Montageart



DIN-Schiene



Fehlerstrom-Typ



A



Selektiver-Typ



nein



Kurzschlussfestigkeit (Icw)


kA
10



Stoßstromfestigkeit


kA
3



Frequenz



50 Hz



Zusatzeinrichtungen möglich



ja



Schutzart (IP)



IP20



Baugröße (nach DIN 43880)



1



Breite in Teilungseinheiten



4



Einbautiefe


mm
70.5



Kurzzeitverzögerter Typ



ja


€69.96
€79.50
Eaton PLSM-B10/1N-MW LS-Schalter 10A/1pol+N/B 242245
Eaton PLSM-B10/1N-MW LS switch 10A/1pol+N/B 242245
2-5 Tage
Cable switchMeasurement switching capacity according to EN 60898:10kAInteractive neutral conductor: yesProtection type (IP):IP20Construction width:26,3mmSize (according to DIN 43880):1.5, Number of poles:1+NTrigger characteristic:BMeasurement voltage:230/400AC48DCV, rated current:10AInstallation depth:60mmType of voltage:AC/DCFrequency:50/60Hz
€7.50
Eaton PLSM-C16/3N-MW Leitungsschutzschalter LS Schalter 242543
On sale!
Eaton PLSM-C16/3N-MW circuit breaker LS switch 242543
1-5 Tage
LS switch 16A/3pol+N/CMeasurement switching capacity according to EN 60898:10kAInteractive neutral conductor: yesProtection type (IP):IP20Construction width:70mmSize (according to DIN 43880):4Number of poles:3+NTrigger characteristic:CMeasurement voltage:230/400AC48DCV, Rated current:16AInstallation depth:60mmType of voltage:AC/DCFrequency:50/60Hz
€33.90
Eaton ZV-SS Sammelschiene, 1m, 50A
On sale!
Eaton ZV-SS busbar, 1m, 50A
2-5 Tage
Plug-in for PLS., CLS., PKN., PFIM, PFHM, (with auxiliary switch), any switchgear combinations with or without auxiliary switch possible, only a few components, 2 angle types per rail cross-section for three-phase displacement, common cover profile with end caps for ZV-SS etc. ZV-SS-80AShort-circuit and insulation resistance tested according to IEC/EN 60439-1Measurement current In A: 50Version: flatGalvanized: NoLength mm: 1000Width mm: 8Height mm: 2Flexible: no
€6.95
Eaton Leitungsschutzschalter LS Schalter PLN6-B13/1-MW
Eaton PLN6-B13/1N Leitungsschutzschalter 1TE LS Schalter
2-5 days
Eaton LS switch, 13A/1pol+N/B, 1TE High-quality cable protection switch 1P+N in 1TE for space-saving installationContact position indicator red-greenClamping aid protectionextensive accessory program retrofittableMeasurement currents up to 40 AMeasurement switching capacity 6 kA according to IEC/EN 60898-1Suitable for outdoor use (conveyor and outdoor distributor) up to - 25°Ctrigger characteristic BNumber of poles (total) 2Rated current 13 AMeasurement voltage 230 VMeasurement switching capacity according to EN 60898 6 kAMeasurement switching capacity Icn according to EN 60898 at 230 V 6 kAMeasurement switching capacity according to IEC 60947-2 0 kAMeasurement switching capacity Icu according to IEC 60947-2 at 230 V 0 kAVoltage type ACEnergy limiting class 3Frequency 50 HzInteractive neutral conductor noOvervoltage category 3Level 2Width in division units 1Installation depth 69.5 mmAdditional equipment possible yesProtection (IP) IP20
€12.71
Eaton PLSM-C25/3N-MW LS-Schalter 25A/3pol+N/C 242545
Eaton PLSM-C25/3N-MW LS switch 25A/3pol+N/C 242545
2-5 days




Trigger characteristic



C



Number of poles (total)



4



Number of secured poles



4



Rated current


A
25



Measurement voltage


V
400



Measurement switching capacity Icn according to EN 60898 at 230 V


KA
10



Measurement switching capacity Icn according to EN 60898 at 400 V


KA
10



Measurement switching capacity Icu according to IEC 60947-2 at 230 V


KA
0



Measurement switching capacity Icu according to IEC 60947-2 at 400 V


KA
0



Type of voltage



AC



Energy limiting class



3



Frequency


HZ
50 to 60



Interconnecting neutral conductor



yes



Suitable for underground installation



no



Overvoltage category



3



Pollution



2



Width in division units



4



Installation depth


mm
ANNEX



Additional equipment possible



yes



Type of protection (IP)



IP20


€58.80
Eaton Z-TS40/3 Tarifschalter 3polig, 25-40A 266860
Eaton Z-TS40/3 3-pole, 25-40A 266860
2-5 days
Switching device for the voluntary or tariff current limitation of consumer equipment, version according to EN/IEC 60898-1, EN/IEC 60947, EVU-approbated, easy to switch on from the current customer, setting screw under a sealable cap
€56.04
EATON PLSM-B10-MW LS-Schalter 10A/1pol/B 242176
EATON PLSM-B10-MW LS switch 10A/1pol/B 242176
2-5 days
Cable switchMeasurement switching capacity according to EN 60898:10kA Interactive neutral conductor:no Protection type (IP):IP20 Construction width:17,5mm Size (according to DIN 43880):1 Number of poles:1 Measurement voltage:230/400AC 48DCV Rated current:10A Installation depth:60mm Voltage type:AC/DC Frequency:50/60Hz
€5.45
Eaton PLSM-C13/3-MW LS-Schalter 13A/3pol/C 242472
Eaton PLSM-C13/3-MW LS switch 13A/3pol/C 242472
2-5 days
Trigger characteristicCNumber of poles (total)3Number of secured poles3Rated currentA13Measurement voltageV400Measurement switching capacity Icn according to EN 60898 at 230 VKA10Measurement switching capacity Icn according to EN 60898 at 400 VKA10Measurement switching capacity Icu according to IEC 60947-2 at 230 VKA0Measurement switching capacity Icu according to IEC 60947-2 at 400 VKA0Type of voltageACEnergy limiting class3FrequencyHZ50 to 60Interconnecting neutral conductornoSuitable for underground installationnoOvervoltage category3Pollution2Width in division units3Installation depthmmANNEXAdditional equipment possibleyesType of protection (IP)IP20
€31.94
Eaton PLSM-B20/3N-MW LS-Schalter 20A/3pol+N/B 242518
Eaton PLSM-B20/3N-MW LS switch 20A/3pol+N/B 242518
2-5 days




Trigger characteristic



B



Number of poles (total)



4



Number of secured poles



4



Rated current


A
20



Measurement voltage


V
400



Measurement switching capacity Icn according to EN 60898 at 230 V


KA
10



Measurement switching capacity Icn according to EN 60898 at 400 V


KA
10



Measurement switching capacity Icu according to IEC 60947-2 at 230 V


KA
0



Measurement switching capacity Icu according to IEC 60947-2 at 400 V


KA
0



Type of voltage



AC



Energy limiting class



3



Frequency


HZ
50 to 60



Interconnecting neutral conductor



yes



Suitable for underground installation



no



Overvoltage category



3



Pollution



2



Width in division units



4



Installation depth


mm
ANNEX



Additional equipment possible



yes



Type of protection (IP)



IP20


€60.44